PFLITSCH fire protection solutions –
when it comes to safety, we are right on track
The railway industry has extremely strict requirements for its components, as safety is a top priority in the sector. Firstly, locomotives, carriages and the entire rail infrastructure all need to function in a reliably. Secondly, it is imperative to guarantee the best possible protection for passengers. Accordingly, the train safety concept is highly complex and applies to the entire railway vehicle. It includes interior and exterior installations and covers a wide variety of aspects, such as fire protection and electromagnetic compatibility (EMC).
Reliable protection – for every train
PFLITSCH offers you a coordinated range of certified cable glands and cable routing solutions for this purpose – and always has the right solution for every application. They meet the diverse and stringent fire protection requirements of the railway industry and guarantee you an outstanding level of reliability. Moreover, they have proven their efficiency in countless railway technology applications over a great many years. In other words, PFLITSCH solutions give you the certainty of always being on the safe side.
documentCreationDateTime: 2024-05-08
fileUploadDateTime: 2026-08-27
8.0 MB
EN
The advantages of our fire protection solutions
A wide range of cable glands and cable entries
Fire protection standards, including models with effective EMC shielding
High strain relief and tightness with protection ratings up to IP 68 and IP 69
For both interior and exterior use, extremely weather- and temperature-resistant
Protection from stone chipping and vibrations
Proven EMC cable glands for effective screening attenuation
Low total costs across the entire life cycle
Above-average durability and time- and cost-saving ease of installation
Typical applications in trains
Fire protection cable glands
At first glance, cable glands play no more than a secondary role in the overall safety concept of a railway vehicle. However, they are indispensable when it comes to ensuring reliable, seamless fire protection in trains, as the primary aim is that every component and all the materials used fundamentally contribute to either preventing a fire or limiting its spread and the resulting consequences. In view of the increasing level of automation in railway technology, not only certified fire protection but also effective EMC protection are becoming more important than ever.
Cable routing
Our product range also includes cable routing solutions. Cables used for transmitting data, signals and electricity need to be routed on both the inside and the outside of the train. To install them both safely and with sufficient protection, PFLITSCH offers its tried-and-tested Wire-tray Trunking system, which is ideally suited for use in the railway industry because of its robust yet lightweight design. As a customised solution with a partition wall already welded in, it also ensures that cables are clearly routed.
The advantages of our Wire-tray Trunking system
- Robust PFLITSCH Wire-tray Trunking provides ideal protection
- Customised solutions (e.g. Wire-tray Trunking with welded partition wall/for the customer Stadler)
- Wire-tray Trunking available in a variety of materials and shapes for maximum cable routing flexibility
- PFLITSCH component assembly service for precisely fitting, ready-to-install solutions that guarantee an efficient process
Standards and certificates
PFLITSCH products meet the international requirements for use in the railway industry. This means they can be used worldwide without the need for additional on-site testing. To ensure this remains the case in the long term, our products are regularly tested and certified in accordance with the latest standards. In recent tests, they have once again been certified and their performance values confirmed. In some cases, these are significantly higher than the required test values. In the field of fire protection, our cable glands meet the highest relevant requirements for hazard levels HL2 and HL3. PFLITSCH fire protection cable glands therefore represent the state of the art and are suitable for use in all areas of rail transport – on open track, in tunnels and in stations.
Flammability rating according to EN 45545
A number of norms and standards have been created to test the two essential criteria of fire protection, i.e. the control of the spread of smoke and fire and the containment of harmful smoke and gas development. Apart from the globally recognised EN 45545-2 and EN 45545-3 standards, which cover both areas, manufacturer- and association-specific standards such as the Bombardier standard SMP 800 and the US NFPA standard also play an important role.
EN 45545-2 for – Material testing
The fire protection requirements for cable glands depend firstly on where they are to be used in the train and are divided into interior (R22) and exterior (R23) use categories. Secondly, the hazard level (HL) of the train is also an important factor, which is determined by the operation category and the design category. The material testing itself verifies compliance with the threshold values for oxygen content, flue gas density and toxicity.
EN 45545-3 – Fire resistance of fire barriers test
Complete cable glands undergo the “Integrity” fire resistance test. In our case, that means the UNI Dicht and blueglobe cable glands as well as the blind plugs. The demanding E30 fire resistance class was achieved in the test. In concrete terms, this means the cable glands are fire-resistant for 30 minutes, which is twice as long as required in accordance with EN 45545-3 (E15 = 15 minutes).
Bombardier standard SMP 800
The Bombardier standard SMP 800 is designed to test the emission of toxic vapours by the sealing inserts of cable glands in the event of fire. Both PFLITSCH fire protection sealing inserts made of TPE and silicone are well below the limit values.
NFPA standard
The US NFPA standard is also important. The tests examine properties such as heat development and visible smoke release rates. These properties were also tested for our fire-resistant sealing inserts made from TPE and silicone: both passed the tests successfully.
Downloads
|
Catalogue cable gland – 10 Fire Protection Cable Glands
New
heute - 60: 2026-07-14
documentCreationDateTime: 2024-05-08 fileUploadDateTime: 2026-09-03 |
09/03/26 |
Cable gland |
2.5 MB | EN | Download | ||
|
Classification report R25/0411 EN 45545-2 R22/23 T80
heute - 60: 2026-07-14
documentCreationDateTime: 2024-05-08 fileUploadDateTime: 2025-11-21 |
11/21/25 |
Cable gland |
808.4 KB | EN | Download | ||
|
Test report R25/0843B NFPA 130 T80
heute - 60: 2026-07-14
documentCreationDateTime: 2026-01-16 fileUploadDateTime: 2026-01-16 |
01/16/26 |
Cable gland |
6.6 MB | EN | Download | ||
|
Test report R25/0843A SMP 800-C T80
heute - 60: 2026-07-14
documentCreationDateTime: 2026-01-16 fileUploadDateTime: 2026-01-16 |
01/16/26 |
Cable gland |
667.9 KB | EN | Download | ||
|
Test report R25/0435M EN 45545-3 burning behaviour UNI Dicht brass/T80
heute - 60: 2026-07-14
documentCreationDateTime: 2024-05-08 fileUploadDateTime: 2025-12-05 |
12/05/25 |
Cable gland |
3.9 MB | EN | Download | ||
|
Test report R25/0435C EN 45545-3 burning behaviour blueglobe brass/T80
heute - 60: 2026-07-14
documentCreationDateTime: 2024-05-08 fileUploadDateTime: 2025-12-05 |
12/05/25 |
Cable gland |
4.2 MB | EN | Download | ||
|
Test report R24/0701E EN 45545-2 oxygen index PC
heute - 60: 2026-07-14
documentCreationDateTime: 2024-05-08 fileUploadDateTime: 2025-11-21 |
11/21/25 |
Cable gland |
5.1 MB | EN | Download | ||
|
Test report R25/0435E EN 45545-3 burning behaviour blueglobe PA/T80
heute - 60: 2026-07-14
documentCreationDateTime: 2024-05-08 fileUploadDateTime: 2025-11-21 |
11/21/25 |
Cable gland |
5.3 MB | EN | Download | ||
|
Test report R25/0435J EN 45545-3 burning behaviour blueglobe brass/S55
heute - 60: 2026-07-14
documentCreationDateTime: 2024-05-08 fileUploadDateTime: 2025-11-21 |
11/21/25 |
Cable gland |
5.3 MB | EN | Download | ||
|
Test report R25/0435G EN 45545-3 burning behaviour UNI Dicht brass/S55
heute - 60: 2026-07-14
documentCreationDateTime: 2024-05-08 fileUploadDateTime: 2025-11-21 |
11/21/25 |
Cable gland |
5.1 MB | EN | Download | ||
|
Test report R24/0701K EN 45545-2 smoke generation/toxicity PA66
heute - 60: 2026-07-14
documentCreationDateTime: 2024-05-08 fileUploadDateTime: 2025-11-21 |
11/21/25 |
Cable gland |
1.7 MB | EN | Download | ||
|
Test report R24/0701H EN 45545-2 smoke generation/toxicity PA6
heute - 60: 2026-07-14
documentCreationDateTime: 2024-05-08 fileUploadDateTime: 2025-11-21 |
11/21/25 |
Cable gland |
1.8 MB | EN | Download | ||
|
Test report R24/0701B EN 45545-2 smoke generation/toxicity S55
heute - 60: 2026-07-14
documentCreationDateTime: 2024-05-08 fileUploadDateTime: 2025-11-21 |
11/21/25 |
Cable gland |
1.9 MB | EN | Download | ||
|
Test report R24/0701F EN 45545-2 smoke generation/toxicity PC
heute - 60: 2026-07-14
documentCreationDateTime: 2024-05-08 fileUploadDateTime: 2025-11-21 |
11/21/25 |
Cable gland |
2.0 MB | EN | Download | ||
|
Test report R24/0701J EN 45545-2 oxygen index PA66
heute - 60: 2026-07-14
documentCreationDateTime: 2024-05-08 fileUploadDateTime: 2025-11-21 |
11/21/25 |
Cable gland |
5.1 MB | EN | Download | ||
|
Test report R24/0701G EN 45545-2 oxygen index PA6
heute - 60: 2026-07-14
documentCreationDateTime: 2024-05-08 fileUploadDateTime: 2025-11-21 |
11/21/25 |
Cable gland |
5.1 MB | EN | Download | ||
|
Test report R24/0701A EN 45545-2 oxygen index S55
heute - 60: 2026-07-14
documentCreationDateTime: 2024-05-08 fileUploadDateTime: 2025-11-21 |
11/21/25 |
Cable gland |
5.1 MB | EN | Download |